{"id":730,"date":"2010-11-18T18:06:49","date_gmt":"2010-11-19T01:06:49","guid":{"rendered":"http:\/\/www.serialporttool.com\/sptblog\/?p=730"},"modified":"2010-11-18T18:06:49","modified_gmt":"2010-11-19T01:06:49","slug":"zigbee-link-testing-with-zigbee-operator","status":"publish","type":"post","link":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/","title":{"rendered":"ZigBee Link Testing with ZigBee Operator"},"content":{"rendered":"<p>ZigBee Operator support \u201cExplicit Addressing ZigBee Command\u201d. We can use Explicit Addressing ZigBee Command for link testing with API firmware.<\/p>\n<p><a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image12.png\"><img loading=\"lazy\" decoding=\"async\" class=\"\" style=\"background-image: none; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png\" alt=\"image\" width=\"619\" height=\"148\" border=\"0\" \/><\/a><\/p>\n<p>Steps for Link Testing<\/p>\n<p>Prepare the mesh network. The minimum requirement for a mesh network is a coordinator and an end device. We use a end device with API firmware.<\/p>\n<p>Power on both coordinator and end devices. Connect the coordinator to the computer.<\/p>\n<p>Open the ZigBee Operator and connect with serial port of XBee modules.<\/p>\n<p>Go to \u201cTools-XBee Devices Properties\u201d or \u201c<a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image1.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; margin: 0px; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border-width: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb1.png\" alt=\"image\" width=\"38\" height=\"37\" border=\"0\" \/><\/a> \u201d icon to open Properties window and check \u201cAPI\u201d check box. Click \u201cRead\u201d button to make sure the computer can talk to device correctly.<\/p>\n<p><a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image13.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb13.png\" alt=\"image\" width=\"378\" height=\"466\" border=\"0\" \/><\/a><\/p>\n<p>Go to \u201cTools-&gt;Search XBee Devices\u201d or click \u201c<a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image3.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; margin: 0px; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border-width: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb3.png\" alt=\"image\" width=\"40\" height=\"38\" border=\"0\" \/><\/a>\u201dicon to open \u201cSearch Device\u201d window and check \u201cAPI Mode\u201d. Click \u201cSearch Network\u201d button to search the network to make sure the end device are connected with Coordinator.<\/p>\n<p><a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image14.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb14.png\" alt=\"image\" width=\"665\" height=\"440\" border=\"0\" \/><\/a><\/p>\n<p>Click \u201cAdd To Database\u201d button to add all XBee modules\u2019 information to database.<\/p>\n<p>Close the search window.<\/p>\n<p>Click \u201cView-&gt;XBee &amp; XBee Pro ZB ZigBee\u201d or \u201c<a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image5.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; margin: 0px; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border-width: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb5.png\" alt=\"image\" width=\"92\" height=\"43\" border=\"0\" \/><\/a>\u201d icon to switch to \u201cMesh Network\u201d panel.<\/p>\n<p><a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image15.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb15.png\" alt=\"image\" width=\"740\" height=\"177\" border=\"0\" \/><\/a><\/p>\n<p>Select \u201cExplicit Addressing ZigBee Command\u201d in type<\/p>\n<p>Select Coordinator\u2019s address in Address<\/p>\n<p>Set \u201cCluster ID\u201d to 12 and \u201cSource Endpoint\u201d to E8 and \u201cDestination Endpoint\u201d to E8.<\/p>\n<p>Set \u201cProfile ID\u201d to C105<\/p>\n<p>Select \u201cTEXT\u201d in format and input \u201cEcho\u201d in RF Data. It can be any text as long as it is not empty.<\/p>\n<p>Click \u201cSend\u201d button.<\/p>\n<p>It will send the data to coordinator endpoint E8 from\u00a0 source endpoint using cluster ID 12. This is setting for Loopback data. When coordinator received data from end point E8, it will send the data back.<\/p>\n<p>Here is the data in log window.<\/p>\n<blockquote><p><span style=\"color: #ff0000;\">Send:(09:03:46) 7E 00 18 11 01 00 13 A2 00 40 0A 2A 94 FF FE E8 E8 00 12 C1 05 00 00 45 63 68 6F 0C <\/span><\/p>\n<p><span style=\"color: #ff0000;\">Data Parsed: 7E 00 18 11 01 00 13 A2 00 40 0A 2A 94 FF FE E8 E8 00 12 C1 05 00 00 45 63 68 6F 0C<br \/>\nExplicit Addressing ZigBee Command<br \/>\nFrame ID: 0x01<br \/>\n64 Bits Address: 0013:A200-400A:2A94<br \/>\n16 Bits Network Address: FFFE<br \/>\nSource Endpoint: 0xE8<br \/>\nDestination Endpoint: 0xE8<br \/>\nCluster ID: 0x0012<br \/>\nProfile ID: 0xC105<br \/>\nBroadcast Radius: 0x00<br \/>\nOptions: 0x00<br \/>\nData(Hex):45 63 68 6F<br \/>\nData(Text):Echo<\/span><\/p>\n<p><span style=\"color: #0000ff;\">Rec:(09:03:47)7E 00 07 8B 01 85 BB 00 00 00 33 7E 00 10 90 00 13 A2 00 40 0A 2A 94 85 BB 41<br \/>\nData Parsed: 7E 00 07 8B 01 85 BB 00 00 00 33<br \/>\nTransmit Status<br \/>\nFrame ID: 1<br \/>\nNetwork Address :0x85BB<br \/>\nRetries: 0x00<br \/>\nDelivery Status: 0x0 = Success<br \/>\nDiscovery Status: 0x0 = No Discovery Overhead<\/span><\/p>\n<p><span style=\"color: #0000ff;\">45 63 68 6F B2<br \/>\nData Parsed: 7E 00 10 90 00 13 A2 00 40 0A 2A 94 85 BB 41 45 63 68 6F B2<br \/>\nZigBee Receive Packet<br \/>\n64 Bits Address: 0013:A200-400A:2A94<br \/>\n16 Bits Network Address: 85BB<br \/>\nOptions: 0x41<br \/>\nPacket Acknowledged<br \/>\nData(Hex):45 63 68 6F<br \/>\nData(Text):Echo<br \/>\n<\/span><\/p><\/blockquote>\n<p>Sometimes, the data send won\u2019t be echo back. Please keep sending until you get the data back. Some times you need reset the end devices.<\/p>\n<p><strong>To check the signal strength on the remote module.<\/strong><\/p>\n<p>Switch to \u201cRemote AT Command\u201d, and select the address of the remote module and send \u201cDB\u201d Command. It will return the signal strength of last hop.<\/p>\n<p><a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image16.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb16.png\" alt=\"image\" width=\"742\" height=\"179\" border=\"0\" \/><\/a><\/p>\n<p>Here is the data in log window.<\/p>\n<blockquote><p><span style=\"color: #ff0000;\">Send:(09:04:51) 7E 00 0F 17 01 00 13 A2 00 40 0A 2A 94 FF FE 00 64 62 67 <\/span><\/p>\n<p><span style=\"color: #ff0000;\">Data Parsed: 7E 00 0F 17 01 00 13 A2 00 40 0A 2A 94 FF FE 00 64 62 67<br \/>\nRemote AT Command<br \/>\nFrame ID: 0x01<br \/>\n64Bits Destination Address: 0013:A200-400A:2A94<br \/>\n16Bits Destination Network Address: FFFE<br \/>\nCommand Options: 0x00<br \/>\nCommand: db<br \/>\nPara(Hex):<br \/>\nPara(Text):<\/span><\/p>\n<p><span style=\"color: #0000ff;\">Rec:(09:04:51)7E 00 10 97 01 00 13 A2 00 40 0A 2A 94 85 BB 64 62 00 24 80<br \/>\nData Parsed: 7E 00 10 97 01 00 13 A2 00 40 0A 2A 94 85 BB 64 62 00 24 80<br \/>\nRemote AT Command Response<br \/>\nFrame ID: 0x01<br \/>\n64Bits Remote Module Address: 0013:A200-400A:2A94<br \/>\n16Bits Remote Module Network Address: 85BB<br \/>\nCommand: db<br \/>\nStatus: 0x00 = OK<br \/>\nPara: 24<br \/>\n<\/span><\/p><\/blockquote>\n<p>The signal strength on remote module is 24.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>To Check the signal strength on the local module.<\/strong><\/p>\n<p>Switch to \u201cAT Command\u201d and send \u201cDB\u201d command. It will return the strength of the last hop.<\/p>\n<p><a href=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image17.png\"><img loading=\"lazy\" decoding=\"async\" style=\"background-image: none; padding-left: 0px; padding-right: 0px; display: inline; padding-top: 0px; border: 0px;\" title=\"image\" src=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb17.png\" alt=\"image\" width=\"732\" height=\"175\" border=\"0\" \/><\/a><\/p>\n<p>Here is the data in log window.<\/p>\n<blockquote><p><span style=\"color: #ff0000;\">Send:(09:09:55) 7E 00 04 08 01 64 62 30 <\/span><\/p>\n<p><span style=\"color: #ff0000;\">Data Parsed: 7E 00 04 08 01 64 62 30<br \/>\nAT Command<br \/>\nFrame ID: 0x01<br \/>\nCommand: db<br \/>\nPara(Hex):<br \/>\nPara(Text):<\/span><\/p>\n<p><span style=\"color: #0000ff;\">Rec:(09:09:55)7E 00 06 88 01 64 62 00 25 8B<br \/>\nData Parsed: 7E 00 06 88 01 64 62 00 25 8B<br \/>\nAT Command Response<br \/>\nFrame ID: 1<br \/>\nCommand: db<br \/>\nStatus: 0 = OK<br \/>\nPara: 25\u00a0 <\/span><\/p><\/blockquote>\n<p>The signal strength of local module for last hop is 25.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>ZigBee Operator support \u201cExplicit Addressing ZigBee Command\u201d. We can use Explicit Addressing ZigBee Command for link testing with API firmware. Steps for Link Testing Prepare the mesh network. The minimum requirement for a mesh network is a coordinator and an [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[46,45],"class_list":["post-730","post","type-post","status-publish","format-standard","hentry","category-zigbee","tag-loopback-explicit-addressing-zigbee","tag-zigbee-operator"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ZigBee Link Testing with ZigBee Operator - Serial Port Tool<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ZigBee Link Testing with ZigBee Operator - Serial Port Tool\" \/>\n<meta property=\"og:description\" content=\"ZigBee Operator support \u201cExplicit Addressing ZigBee Command\u201d. We can use Explicit Addressing ZigBee Command for link testing with API firmware. Steps for Link Testing Prepare the mesh network. The minimum requirement for a mesh network is a coordinator and an [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/\" \/>\n<meta property=\"og:site_name\" content=\"Serial Port Tool\" \/>\n<meta property=\"article:published_time\" content=\"2010-11-19T01:06:49+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png\" \/>\n<meta name=\"author\" content=\"xushirui\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"xushirui\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/\"},\"author\":{\"name\":\"xushirui\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#\/schema\/person\/f588b4f9d1e2e18ebc56957bcdb417cf\"},\"headline\":\"ZigBee Link Testing with ZigBee Operator\",\"datePublished\":\"2010-11-19T01:06:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/\"},\"wordCount\":649,\"publisher\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png\",\"keywords\":[\"Loopback; Explicit Addressing; zigbee\",\"ZigBee Operator\"],\"articleSection\":[\"ZigBee &amp; XBee\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/\",\"name\":\"ZigBee Link Testing with ZigBee Operator - Serial Port Tool\",\"isPartOf\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png\",\"datePublished\":\"2010-11-19T01:06:49+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage\",\"url\":\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png\",\"contentUrl\":\"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.serialporttool.com\/GK\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ZigBee Link Testing with ZigBee Operator\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#website\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/\",\"name\":\"Serial Port Tool\",\"description\":\"Software Solution for Serial Port and Network Control\",\"publisher\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.serialporttool.com\/GK\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#organization\",\"name\":\"Ginkgo LLC\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png\",\"contentUrl\":\"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png\",\"width\":565,\"height\":128,\"caption\":\"Ginkgo LLC\"},\"image\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#\/schema\/person\/f588b4f9d1e2e18ebc56957bcdb417cf\",\"name\":\"xushirui\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d4eaaf6aba2e36365bc8d8ca8dca05e05082a6df3df53c180d609d133fa2ae3f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d4eaaf6aba2e36365bc8d8ca8dca05e05082a6df3df53c180d609d133fa2ae3f?s=96&d=mm&r=g\",\"caption\":\"xushirui\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ZigBee Link Testing with ZigBee Operator - Serial Port Tool","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/","og_locale":"en_US","og_type":"article","og_title":"ZigBee Link Testing with ZigBee Operator - Serial Port Tool","og_description":"ZigBee Operator support \u201cExplicit Addressing ZigBee Command\u201d. We can use Explicit Addressing ZigBee Command for link testing with API firmware. Steps for Link Testing Prepare the mesh network. The minimum requirement for a mesh network is a coordinator and an [&hellip;]","og_url":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/","og_site_name":"Serial Port Tool","article_published_time":"2010-11-19T01:06:49+00:00","og_image":[{"url":"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png","type":"","width":"","height":""}],"author":"xushirui","twitter_card":"summary_large_image","twitter_misc":{"Written by":"xushirui","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#article","isPartOf":{"@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/"},"author":{"name":"xushirui","@id":"https:\/\/www.serialporttool.com\/GK\/#\/schema\/person\/f588b4f9d1e2e18ebc56957bcdb417cf"},"headline":"ZigBee Link Testing with ZigBee Operator","datePublished":"2010-11-19T01:06:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/"},"wordCount":649,"publisher":{"@id":"https:\/\/www.serialporttool.com\/GK\/#organization"},"image":{"@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage"},"thumbnailUrl":"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png","keywords":["Loopback; Explicit Addressing; zigbee","ZigBee Operator"],"articleSection":["ZigBee &amp; XBee"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/","url":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/","name":"ZigBee Link Testing with ZigBee Operator - Serial Port Tool","isPartOf":{"@id":"https:\/\/www.serialporttool.com\/GK\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage"},"image":{"@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage"},"thumbnailUrl":"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png","datePublished":"2010-11-19T01:06:49+00:00","breadcrumb":{"@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#primaryimage","url":"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png","contentUrl":"http:\/\/www.serialporttool.com\/sptblog\/wp-content\/uploads\/2010\/11\/image_thumb12.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.serialporttool.com\/GK\/2010\/11\/zigbee-link-testing-with-zigbee-operator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.serialporttool.com\/GK\/"},{"@type":"ListItem","position":2,"name":"ZigBee Link Testing with ZigBee Operator"}]},{"@type":"WebSite","@id":"https:\/\/www.serialporttool.com\/GK\/#website","url":"https:\/\/www.serialporttool.com\/GK\/","name":"Serial Port Tool","description":"Software Solution for Serial Port and Network Control","publisher":{"@id":"https:\/\/www.serialporttool.com\/GK\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.serialporttool.com\/GK\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.serialporttool.com\/GK\/#organization","name":"Ginkgo LLC","url":"https:\/\/www.serialporttool.com\/GK\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/","url":"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png","contentUrl":"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png","width":565,"height":128,"caption":"Ginkgo LLC"},"image":{"@id":"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.serialporttool.com\/GK\/#\/schema\/person\/f588b4f9d1e2e18ebc56957bcdb417cf","name":"xushirui","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.serialporttool.com\/GK\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d4eaaf6aba2e36365bc8d8ca8dca05e05082a6df3df53c180d609d133fa2ae3f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d4eaaf6aba2e36365bc8d8ca8dca05e05082a6df3df53c180d609d133fa2ae3f?s=96&d=mm&r=g","caption":"xushirui"}}]}},"_links":{"self":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/posts\/730","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/comments?post=730"}],"version-history":[{"count":0,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/posts\/730\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/media?parent=730"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/categories?post=730"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/tags?post=730"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}