{"id":6239,"date":"2019-06-10T14:53:00","date_gmt":"2019-06-10T19:53:00","guid":{"rendered":"http:\/\/www.serialporttool.com\/GK\/?page_id=6239"},"modified":"2019-06-10T15:17:54","modified_gmt":"2019-06-10T20:17:54","slug":"relay-timer-user-manual","status":"publish","type":"page","link":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/","title":{"rendered":"Relay Timer User Manual"},"content":{"rendered":"<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png\" alt=\"\"\/><\/figure><\/div><p style=\"text-align:center\"><a href=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUIFull.png\">Click to see full size<\/a><\/p><a href=\"#configure\"class=\"link_text\" style=\"line-height: 25px; text-recreation:underline;\">1. How to Configure<\/a><br \/>\n              <a href=\"#manually\"class=\"link_text\" style=\"line-height: 25px;\">2. How to Turn On\/Off Relay Manually<\/a><br \/>\n              <a href=\"#automatically\"class=\"link_text\" style=\"line-height: 25px;\">3. How to Turn On\/Off Relay Automatically<\/a><br \/>\n              <a href=\"#customize\"class=\"link_text\" style=\"line-height: 25px;\">4. How to Customize Relay Status<\/a><br \/>\n              <a href=\"#commandline\"class=\"link_text\" style=\"line-height: 25px;\">5. How to Launch with Command Line<\/a><br \/>\n              <a href=\"#remotecontrol\"class=\"link_text\" style=\"line-height: 25px;\">6. How to Control Relay Remotely<\/a><br \/>\n                  <a href=\"#rapidButtons\"class=\"link_text\" style=\"line-height: 25px;\">7. Rapid Buttons  <\/a>\n<a name=\"top\"><\/a><hr class=\"wp-block-separator is-style-wide\"\/><p class=\"smallTitleInUserManual\">\n                  <a name=\"configure\" id=\"configure\"><\/a> 1. How to Configure<\/p> \n               \n                    <p class=\"textInUserManual\">\n                        In order to control your device with Relay Timer, be sure to connect NCD \n                        ProXR relay board\n                        with your computer and connect your device with the relay board at first, then set the \n                        configuration as below.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Click <strong>\n                            <img loading=\"lazy\" decoding=\"async\" height=\"31\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnConfig.png\" width=\"115\" \/>\n                        <\/strong>button to open the <strong>Configuration<\/strong> dialog.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/formConfig.png\" width=\"452\" height=\"574\" class=\"textInUserManual\">&nbsp;<\/p>\n                    <p class=\"textInUserManual\">\n                        <strong>ProXR Relay Board: <\/strong>This panel is to manage extension ProXR \n                        relay boards.<\/p>\n                    <p class=\"textInUserManual\">\n                        <strong>Connection:<\/strong> This panel is to set connection ways, Com Port or Network.<\/p>\n                    <p class=\"textInUserManual\">\n                        <strong>Communication: <\/strong>This panel is to set communication parameters. \n                        The default is two-way communication.<\/p>\n                    <p class=\"textInUserManual\">\n                        <strong>Romate Access: <\/strong>Select &quot;Enable Control Relmotely&quot; checkboxt to activate Romote \n                        Access. Relay Timer can be controlled from other computer by visting the current \n                        computer&#39;s IP address.<\/p>\n                    <p class=\"textInUserManual\">\n                        Select &quot;Auto run after login Windows&quot; checkbox, Relay Timer will be run after \n                        login Windows automatically.<\/p>\n                    <p align=\"left\" class=\"textInUserManual\">\n                        Click <strong>OK<\/strong> to finish setting.\n                    <\/p>\n                \n                <p align=\"right\">\n                <a href=\"#top\" class=\"link_text\" >Back to top<\/a>\n                <\/p><hr class=\"wp-block-separator is-style-wide\"\/><p class=\"smallTitleInUserManual\">\n                       <a name=\"manually\" id=\"manually\"><\/a>2. How to Turn On\/Off Relay Manually\n                   <\/p>\n  \n                    <p class=\"textInUserManual\">\n                        <span class=\"textInUserManual\">The light on top right of relay control panel indicates the status\n                            of the relay.<\/span><\/p>\n                    <p class=\"textInUserManual\">\n                        Red is for relay off. Green is for relay on.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Click <strong>\n                            <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/ManualUp.gif\" width=\"75\" height=\"24\"><\/strong> button down\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/ManualDown.gif\" width=\"75\" height=\"24\">\n                        to step into manual operation mode.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Click the slider\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/SwitchOn.gif\" width=\"74\" height=\"24\">\n                        to turn on the relay. The light becomes green.<\/p>\n                    <p class=\"textInUserManual\">\n                        Click the slider\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/SwitchOff.gif\" width=\"74\" height=\"24\">\n                        to turn off the relay. The light becomes red.\n                    <\/p>\n                    <table width=\"691\" border=\"0\">\n                        <tr>\n                            <td width=\"155\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/R16X\/frmRelayAuto.png\" width=\"98\" height=\"254\"><\/span><\/div>\n                            <\/td>\n                            <td width=\"261\">\n                                <div align=\"center\">\n                                    <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/R16X\/frmRelayManualOff.png\" width=\"98\" height=\"254\"><\/div>\n                            <\/td>\n                            <td width=\"261\">\n                                <div align=\"center\">\n                                    <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/R16X\/frmRelayManualOn.png\" width=\"98\" height=\"254\"><\/div>\n                            <\/td>\n                        <\/tr>\n                    <\/table>\n               \n                <p align=\"right\">\n                <a href=\"#top\" class=\"link_text\" >Back to top<\/a>\n                <\/p><hr class=\"wp-block-separator is-style-wide\"\/><p class=\"smallTitleInUserManual\">\n                   <a name=\"automatically\"><\/a>3. How to Turn On\/Off Relay Automatically<\/p>\n          \n                    <p class=\"textInUserManual\">\n                        Click <strong>\n                            <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/AutoUp.gif\" width=\"75\" height=\"24\"><\/strong> button down\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/AutoDown.gif\" width=\"75\" height=\"24\">\n                        to step into auto mode.<\/p>\n                    <p class=\"textInUserManual\">\n                        The default mode is auto mode. The schedule of the relay action must be set at first.<\/p>\n                    <p class=\"textInUserManual\">\n                        Click <strong>\n                            <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/Setting.gif\" width=\"74\" height=\"21\"><\/strong> button on the\n                        relay control panel to open <strong>Relay Setting<\/strong> dialog.\n                    <\/p>\n                <p align=\"left\" class=\"textInUserManual\">\n                    <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formRelaySetting.png\" width=\"730\" height=\"420\">\n                <\/p>\n                <p class=\"textInUserManual\">\n                    The relay can be given a name here.\n                <\/p>\n                <p class=\"textInUserManual\">\n                    Click <strong>Add<\/strong> button to open <strong>Schedule Setting<\/strong> dialog.<\/p>\n                <p align=\"left\" class=\"textInUserManual\">\n                    <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formScheduleSetting.png\" width=\"543\" height=\"480\">\n                <\/p>\n                <p class=\"textInUserManual\">\n                    Edit the <em><strong>Schedule Name<\/strong><\/em>, select<em><strong> Relay Status<\/strong><\/em>,\n                    set <em><strong>Schedule Time<\/strong><\/em>, select<em><strong> Recurrence Pattern<\/strong><\/em>\n                    and <em><strong>Range <\/strong><\/em>.<\/p>\n                <p class=\"textInUserManual\">\n                    Click <strong>OK<\/strong> to return <strong>Relay Setting <\/strong>dialog.<\/p>\n                <p class=\"textInUserManual\">\n                    Different schedules can be added by this way.\n                <\/p>\n                <p align=\"left\" class=\"textInUserManual\">\n                    <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formRelaySettingResult.png\" width=\"730\" height=\"420\"><\/p>\n                <p class=\"textInUserManual\">\n                    Click <strong>OK<\/strong> to finish relay setting.\n                <\/p>\n                <p class=\"textInUserManual\">\n                    The relay will be turned on\/off automatically according to the schedule list.<\/p>\n          \n<p align=\"right\">\n                <a href=\"#top\" class=\"link_text\" >Back to top<\/a>\n                <\/p><hr class=\"wp-block-separator is-style-wide\"\/><p class=\"smallTitleInUserManual\">\n                    <a name=\"customize\"><\/a>4. How to Customize Relay Status \n                <\/p>\n            \n                    <p class=\"textInUserManual\">\n                        The status of relay can be customized except only on or off.<\/p>\n                    <p class=\"textInUserManual\">\n                        For example, relay can be on 10 minutes, off 5 minutes within one hour, and on 20\n                        minutes and off 10 minutes within the other one hour. This can be set as steps below.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Step1. Click <strong>\n                            <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/Setting.gif\" width=\"74\" height=\"21\"><\/strong> button on the\n                        relay control panel to open<strong> Relay Setting<\/strong> dialog.\n                    <\/p>\n                    <p align=\"left\" class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formRelaySetting.png\" width=\"730\" height=\"420\">\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Step 2. Click <strong>Add<\/strong> button to open <strong>Schedule Setting<\/strong>\n                        dialog.<\/p>\n                    <p align=\"left\" class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formScheduleSetting-1.png\" width=\"543\" height=\"480\">\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Edit the <em><strong>Schedule Name<\/strong><\/em>, set <em><strong>Schedule Time<\/strong><\/em>(2\n                        hours), select<em><strong> Recurrence Pattern<\/strong><\/em> and <em><strong>Range <\/strong>\n                        <\/em>.<\/p>\n                    <p class=\"textInUserManual\">\n                        Step 3. Click <em><strong>Customize Action<\/strong><\/em> or the edit button beside\n                        it to open <strong>Customize Action<\/strong> dialog.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formCustomizeAction_1.png\" width=\"560\" height=\"371\"><\/p>\n                    <p class=\"textInUserManual\">\n                        Step 4. Click <strong>Add<\/strong> button to open<strong> Actcion Rule<\/strong>\n                        dialog.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Set <strong><em>Turn On<\/em><\/strong> 10 minutes, <strong><em>Turn Off<\/em><\/strong>\n                        5 minutes and <em><strong>Loop Count<\/strong><\/em> 4.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/frmActionRule_1.png\" width=\"237\" height=\"254\"><\/p>\n                    <p class=\"textInUserManual\">\n                        Click <strong>OK<\/strong> to return <strong>Customize Action <\/strong>dialog. The\n                        action will be shown in the list.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formCustomizeAction_2.png\" width=\"560\" height=\"371\"><\/p>\n                    <p class=\"textInUserManual\">\n                        Step 5. Click Add button to open <a><strong>Actcion Rule<\/strong><\/a>\n                        dialog again.<\/p>\n                    <p class=\"textInUserManual\">\n                        Set <strong><em>Turn On<\/em><\/strong> 20 minutes, <strong><em>Turn Off<\/em><\/strong>\n                        10 minutes and <em><strong>Loop Count<\/strong><\/em> 2.<\/p>\n                    <p class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/frmActionRule_2.png\" width=\"237\" height=\"254\">\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Click <strong>OK<\/strong> to return <strong>Customize Action <\/strong>dialog.The\n                        action will also be shown in the list.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formCustomizeAction_3.png\" width=\"560\" height=\"371\"><\/p>\n                    <p class=\"textInUserManual\">\n                        Click <em><strong>OK<\/strong><\/em> button to return <a><strong>Schedule Setting<\/strong><\/a> dialog and then click <strong><em>OK<\/em><\/strong> button again to return <a><strong>\n                            Relay Setting<\/strong><\/a>\n                        dialog.\n                    <\/p>\n                    <p align=\"left\" class=\"textInUserManual\">\n                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/formRelaySettingResult_1.png\" width=\"730\" height=\"420\">\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        Click <strong>OK<\/strong> to finish relay setting.\n                    <\/p>\n                    <p class=\"textInUserManual\">\n                        The relay will be turned on\/off automatically according to the customized setting.<\/p>\n            \n                <p align=\"right\">\n                <a href=\"#top\" class=\"link_text\" >Back to top<\/a>\n                <\/p><hr class=\"wp-block-separator is-style-wide\"\/><p class=\"smallTitleInUserManual\">\n                <a name=\"commandline\"><\/a>\n                   5. How to Launch with Command Line<\/p>\n\n\t\t\t\t\t      <p class=\"textInUserManual\">Relay Timer supports command line operation. It can be launched with a specified \n                              configuration file or schedule setting file.<\/p>\n                          <p class=\"textInUserManual\">Format: <\/p>\n                          <blockquote><p class=\"textInUserManual\"><strong><em>&quot;Path to RelayTimer.exe&quot; -c &quot;Path \n                              to *.cfg&quot;<\/em><\/strong>&nbsp;&nbsp;&nbsp; <\/p>\n                              <p class=\"textInUserManual\"><strong><em>&quot;Path to RelayTimer.exe&quot; -as &quot;Path \n                              to *.asch&quot;<\/em><\/strong>&nbsp;<\/p>\n                          <\/blockquote>\n\t\t\t\t\t      <p class=\"textInUserManual\">Note: <\/p>\n                          <p class=\"textInUserManual\">The parameter &quot;-c&quot; is to launch a new Relay Timer \n                              instance with the specified configuration file \n                              (*.cfg). Both the contents in Configuration\n                              dialog and all Relay Setting dialogs will \n                              be loaded.&nbsp; \n                              If the *.cfg file does not exist, it will be created in the specified path \n                              automatically. After editing the Configuration dialog and Setting dialogs, the \n                              information will be saved to the created *.cfg file. When the command is run \n                              next time, all information will be loaded.<\/p>\n                          <p class=\"textInUserManual\">The parameter &#8221;-as&#8221; is to launch a new Relay Timer instance with the schedule setting file \n                              (*.asch). The content of Relay \n                              Setting dialog for all relays on all boards will be loaded.&nbsp; \n                              All information will be saved in the default configuration file.<o:p> <\/o:p>\n                              When Relay Timer is launched by Icon on desktop or start menu, it loads the \n                              default configuration file. When you run this command, you need make sure the \n                              current default configuration file is same as when the *.asch file was saved.<o:p><\/o:p><\/p>\n                          <p class=\"textInUserManual\">Example I:<\/p>\n                          <ul>\n                              <li>\n                                  <p class=\"textInUserManual\">\n                                      Click \n                                      Windows Start -&gt; Run cmd.exe to open command line window. <\/p>\n                              <\/li>\n                          <\/ul>\n\n                              <ul>\n                                  <li>\n                                      <p class=\"textInUserManual\">\n                                          Type the command with parameters.<\/p>\n                                      <p class=\"textInUserManual\">\n                                          <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/commandline.png\" width=\"509\" height=\"199\"><\/p>\n                                          <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/commandline_1.png\" width=\"525\" height=\"199\"><\/li>\n                                  <li>\n                                      <p class=\"textInUserManual\">\n                                          Press &#8216;Enter&#8217; key to launch \n                                          Relay Timer with the specified \n                                  configuration file or all schedule setting file. <\/p>\n                                    <\/li>\n                          <\/ul>                      \n\n                       <p class=\"textInUserManual\">Example II:<\/p>\n                          <ul>\n                              <li>\n                                  <p class=\"textInUserManual\">\n                                      Create shortcut for \n                                      RelayTimer.exe in the installation folder.<\/p>\n                          <p class=\"textInUserManual\">\n                                          <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/command_1.png\" width=\"663\" height=\"503\"><\/p>\n                              <\/li>\n                          <\/ul>\n\n                          <ul>\n                              <li>\n                                  <p class=\"textInUserManual\">\n                                      Open &#8216;Properties&#8217; of the shortcut.<\/p>\n                          <p class=\"textInUserManual\">\n                                          <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/command_2.png\" width=\"664\" height=\"503\"><\/p>\n                              <\/li>                          <\/ul>\n\n                          <ul>\n                              <li>\n                                  <p class=\"textInUserManual\">\n                                      Add the arguments shown as below.<\/p>\n                          <p class=\"textInUserManual\">\n                                          <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/command_3.png\" width=\"367\" height=\"509\"><\/p>\n\n                              <\/li>\n                          <\/ul>\n                          <ul>\n                          <li>\n                                  <p class=\"textInUserManual\">\n                                          Double click the shortcut to launch \n                                          Relay Timer with the specified configuration file.&nbsp; <\/p>\n                   \n                          <\/li>\n                          <\/ul>\n\t\t\t\t\t\n<p align=\"right\">\n                <a href=\"#top\" class=\"link_text\" >Back to top<\/a>\n                <\/p><hr class=\"wp-block-separator is-style-wide\"\/><a name=\"remotecontrol\"><\/a><p class=\"smallTitleInUserManual\">\n                   6. How to Control Relay Remotely\n                   <\/p>\n\n                            <P class=textInUserManual>Relay Timer can be controlled remotely from other computers.<\/P>\n                              <P class=textInUserManual>&nbsp;Click <strong>Configure<\/strong> button to show the <A \nhref=\"..\/reference\/config.htm\">Configuration<\/A> dialog.<\/P>\n                              <P class=textInUserManual><img decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/formConfig_5.png\" width=452 \nheight=574><\/P>\n                            <P class=textInUserManual align=left>Select <strong>Enable Control Remotely<\/strong> \n                                checkbox. Set the Port Number or keep default value 80.<\/P>\n                              <P class=textInUserManual align=left>Select <strong>Password<\/strong> to set password for \n                                  remote access.<\/P>\n                            <P class=textInUserManual align=left>Click <STRONG>OK<\/STRONG> to finish setting.<\/P>\n                          \n                                <p class=\"textInUserManual\">\n                                    Relay Timer can be controlled on the other computer by visiting the current \n                                    computer&#39;s IP address in internet browser.<\/p>\n                                <p class=\"textInUserManual\">\n                                    <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/remoteControl.png\" width=\"519\" height=\"372\" \/><\/p>\n                                <p class=\"content\">\n                                    If Port Number is 80, you just need to type the IP address in the brower, shown \n                                    as above.<\/p>\n                                <p class=\"content\">\n                                    If Port Number is modified, you need add the number after the IP address, shown \n                                    as below.<\/p>\n                                <p class=\"content\">\n                                    <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/remoteControl_1.png\" width=\"516\" height=\"384\" \/><\/p>\n                          \n      <p align=\"right\">\n                <a href=\"#top\" class=\"link_text\" >Back to top<\/a>\n                <\/p><hr class=\"wp-block-separator is-style-wide\"\/><p class=\"smallTitleInUserManual\">\n                       7. Rapid Buttons <a name=\"rapidButtons\" id=\"rapidButtons\"><\/a>\n                   <\/p>\n              \n                    <table width=\"600\" border=\"1\" style=\"margin-right: 0px\">\n                        <tr>\n                            <td height=\"47\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnConfig.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to load a *.cfg file to get settings of all relays.<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td height=\"47\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnAllOn.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to turn all relays on.<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td height=\"45\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnAllOff.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to turn all relays off.<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td height=\"46\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnAutoMode.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to set all relays in auto mode.<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td height=\"47\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnLoadStatus.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to load a *.sts file to set status of all relays.<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td height=\"43\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnSaveStatus.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to save current status all relays to a file \n                                (*.sts)<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td height=\"47\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnLoadSetting.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to load a *.sch file to get setting for all relays.<\/span><\/td>\n                        <\/tr>\n                        <tr>\n                            <td height=\"48\" style=\"width: 157px\">\n                                <div align=\"center\">\n                                    <span class=\"textInUserManual\">\n                                        <img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/btnSaveSetting.png\" width=\"116\" height=\"33\"><\/span><\/div>\n                            <\/td>\n                            <td>\n                                <span class=\"textInUserManual\">Click to save settings of all relays to a file (*.sch)<\/span><\/td>\n                        <\/tr>\n                    <\/table>   \n <p align=\"right\">\n                <a href=\"#top\" class=\"link_text\" >Back to top<\/a>\n                <\/p>","protected":false},"excerpt":{"rendered":"<p>Click to see full size 1. How to Configure 2. How to Turn On\/Off Relay Manually 3. How to Turn On\/Off Relay Automatically 4. How to Customize Relay Status 5. How to Launch with Command Line 6. How to Control [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-6239","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Relay Timer User Manual - Serial Port Tool<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Relay Timer User Manual - Serial Port Tool\" \/>\n<meta property=\"og:description\" content=\"Click to see full size 1. How to Configure 2. How to Turn On\/Off Relay Manually 3. How to Turn On\/Off Relay Automatically 4. How to Customize Relay Status 5. How to Launch with Command Line 6. How to Control [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/\" \/>\n<meta property=\"og:site_name\" content=\"Serial Port Tool\" \/>\n<meta property=\"article:modified_time\" content=\"2019-06-10T20:17:54+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/\",\"name\":\"Relay Timer User Manual - Serial Port Tool\",\"isPartOf\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png\",\"datePublished\":\"2019-06-10T19:53:00+00:00\",\"dateModified\":\"2019-06-10T20:17:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#primaryimage\",\"url\":\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png\",\"contentUrl\":\"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.serialporttool.com\/GK\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Relay Timer User Manual\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#website\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/\",\"name\":\"Serial Port Tool\",\"description\":\"Software Solution for Serial Port and Network Control\",\"publisher\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.serialporttool.com\/GK\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#organization\",\"name\":\"Ginkgo LLC\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png\",\"contentUrl\":\"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png\",\"width\":565,\"height\":128,\"caption\":\"Ginkgo LLC\"},\"image\":{\"@id\":\"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Relay Timer User Manual - Serial Port Tool","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/","og_locale":"en_US","og_type":"article","og_title":"Relay Timer User Manual - Serial Port Tool","og_description":"Click to see full size 1. How to Configure 2. How to Turn On\/Off Relay Manually 3. How to Turn On\/Off Relay Automatically 4. How to Customize Relay Status 5. How to Launch with Command Line 6. How to Control [&hellip;]","og_url":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/","og_site_name":"Serial Port Tool","article_modified_time":"2019-06-10T20:17:54+00:00","og_image":[{"url":"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/","url":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/","name":"Relay Timer User Manual - Serial Port Tool","isPartOf":{"@id":"https:\/\/www.serialporttool.com\/GK\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#primaryimage"},"image":{"@id":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#primaryimage"},"thumbnailUrl":"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png","datePublished":"2019-06-10T19:53:00+00:00","dateModified":"2019-06-10T20:17:54+00:00","breadcrumb":{"@id":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#primaryimage","url":"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png","contentUrl":"http:\/\/www.serialporttool.com\/RelayTimer\/tutorials\/images\/RT\/MainGUI.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.serialporttool.com\/GK\/relay-timer-user-manual\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.serialporttool.com\/GK\/"},{"@type":"ListItem","position":2,"name":"Relay Timer User Manual"}]},{"@type":"WebSite","@id":"https:\/\/www.serialporttool.com\/GK\/#website","url":"https:\/\/www.serialporttool.com\/GK\/","name":"Serial Port Tool","description":"Software Solution for Serial Port and Network Control","publisher":{"@id":"https:\/\/www.serialporttool.com\/GK\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.serialporttool.com\/GK\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.serialporttool.com\/GK\/#organization","name":"Ginkgo LLC","url":"https:\/\/www.serialporttool.com\/GK\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/","url":"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png","contentUrl":"https:\/\/www.serialporttool.com\/GK\/wp-content\/uploads\/2019\/07\/SerialPortToolSmallOutline.png","width":565,"height":128,"caption":"Ginkgo LLC"},"image":{"@id":"https:\/\/www.serialporttool.com\/GK\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/pages\/6239","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/comments?post=6239"}],"version-history":[{"count":7,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/pages\/6239\/revisions"}],"predecessor-version":[{"id":6246,"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/pages\/6239\/revisions\/6246"}],"wp:attachment":[{"href":"https:\/\/www.serialporttool.com\/GK\/wp-json\/wp\/v2\/media?parent=6239"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}