LineMode
3000
HH:mm:ss
true
false
false
true
Send:
Rec:
Status:
Red
Black
Blue
0D
MM/dd/yyyy, HH:mm:ss.fff
false
false
1
1
false
false
true
10
10
CS_FF_A_B
Standard
false
1
true
true
Hex
true
Normal
700
600
760
281
230
false
103
Trun Off Relay 1 in Bank 1
Dec
/mQB
254,100-107, Bank Turn Off Individual Relays in Bank
Unchecked
Unchecked
Unchecked
201
100
100
100
Trun Off Relay 1 in Bank 1
Dec
/mQB
254,100-107, Bank Turn Off Individual Relays in Bank
Unchecked
Unchecked
Unchecked
Turn on Relay 1 in Bank 1
Dec
/mwB
254, 108-,115, 1 turn on relay 1 - 8 in bank 1
Unchecked
Unchecked
Unchecked
Trun Off Relay 1 in Bank 2
Dec
/mQC
254,100-107, Bank Turn Off Individual Relays in Bank
Unchecked
Unchecked
Unchecked
Turn on Relay 1 in Bank 2
Dec
/mwC
254, 108-,115, 2 turn on relay 1 - 8 in bank 2
Unchecked
Unchecked
Unchecked
Trun Off Relay 1 in Bank 3
Dec
/mQD
254,100-107, Bank Turn Off Individual Relays in Bank
Unchecked
Unchecked
Unchecked
Turn on Relay 1 in Bank 3
Dec
/mwD
254, 108-,115, 3 turn on relay 1 - 8 in bank 3
Unchecked
Unchecked
Unchecked
Turn On Automatic Relay Refreshing
Dec
/hk=
Turn On Automatic Relay Refreshing
Unchecked
Unchecked
Unchecked
Turn Off Automatic Relay Refreshing
Dec
/ho=
Turn Off Automatic Relay Refreshing
Unchecked
Unchecked
Unchecked
Turn Reporting Mode On
Dec
/hs=
27 Turn Reporting Mode ON
By default, Reporting Mode is off. Reporting mode confirms the completion
of most commands by sending an ASCII character code 85 back
to the user. Reporting mode does NOT confirm the completion of E3C
commands, or any command that sends data back to the user. Reporting
mode is stored in non-volatile memory. Reporting mode slows communications
and is only recommended in high-reliability installations.
Unchecked
Unchecked
Unchecked
Turn Reporting Mode Off
Dec
/hw=
28 Turn Reporting Mode OFF
This command turns off the reporting function. Reporting mode is
stored in non-volatile memory. This is the default setting.
Unchecked
Unchecked
Unchecked
Test Two Ways Communication
Dec
/iE=
This command can be used to test 2-way communication between the
host computer and the relay controller. When executed, the relay controller
will send ASCII character code 85 back to the user. This command
should be used for initial installations if 2-way communication is
required. It can also be used to detect the presence of a relay controller
on the serial port.
Unchecked
Unchecked
Unchecked
Store Relay Refreshing Mode
Dec
/iM=
Store Relay Refreshing Mode
Unchecked
Unchecked
Unchecked
Report Back Stored Refresh Settings
Dec
/iQ=
Report Back Stored Refresh Settings
Unchecked
Unchecked
Unchecked
Manually Refresh Relay Bank
Dec
/iU=
Manually Refresh Relay Bank
Unchecked
Unchecked
Unchecked
Set Status of All Relays
Dec
/iiq
This command is used to set the status of all relays at one time. A single
parameter is required. The equivalent binary pattern of the parameter
is copied directly to the relays, instantly setting the on/off status of
all relays on the board.
170 will set the relays status to
On Off On Off On Off On Off
Unchecked
Unchecked
Unchecked
Store Pattern In Bank
Dec
/ioB
This command stores the current on/off setting of all relays into a memory
bank (0-15). This command is useful for creating macros or for
making sure certain relays are never activated simultaneously.
Unchecked
Unchecked
Unchecked
Recall Pattern in Bank
Dec
/is=
This command recalls a stored relay pattern from the user selected
memory bank (0-15) and update all relays on the board to the settings
defined by command 42 above.
Unchecked
Unchecked
Unchecked
Relay Select
Dec
/iwA
This command turns off all relays and then turns on the selected relay
only. This command performs a safe “Break Before Make”, ensuring
that no two relays are ever activated at the same time.
Unchecked
Unchecked
Unchecked
Turn On Relay 1 in Bank1
Dec
/mwB
254,108-115 Turn On Individual Relays in Bank
Unchecked
Unchecked
Unchecked
Get Status of Relay 1 in Bank 1
Dec
/nQB
254,116-123, Bank Get the Status of an Individual Relay in Bank
This command allows you to read the on/off status of an individual relay.
16 (or 116) corresponds to relay 1, 23 (or 123) corresponds to
relay 8. This command will return a 1 indicating the relay is ON or a 0
indicating the relay is OFF.
NOTICE: A BANK VALUE OF 0 IS INVALID FOR THIS COMMAND.
RETURNED RESULTS MAY BE UNPREDICTABLE.
Unchecked
Unchecked
Unchecked
Get the status of all relays in bank 1
Dec
/nwB
Get the Status of All Relays in Bank
Unchecked
Unchecked
Unchecked
Turn All Relays Off In Bank
Dec
/oEB
254, 129, Bank Turn All Relays On in Bank
This command is used to activate all relays in a selected relay bank.
NOTE: A Bank Value of 0 applies this command to all relay banks.
Unchecked
Unchecked
Unchecked
Turn All Relay On in Bank 1
Dec
/oIB
254, 130, Bank Turn All Relays Off in Bank
This command is used to turn all relays off in a selected relay bank.
NOTE: A Bank Value of 0 applies this command to all relay banks.
Unchecked
Unchecked
Unchecked
Invert All Relays in Bank 1
Dec
/oMB
This command is used to Invert the status of all relays. Relays that
were on turn off, relays that were off turn on.
Unchecked
Unchecked
Unchecked
Reverse All Relays in Bank 1
Dec
/oQB
254, 132, Bank Reverse All Relays in Bank
This command is used to reverse the current pattern of relays in a
given relay bank.
Unchecked
Unchecked
Unchecked
Set the Status of Relays in Bank 1
Dec
/oyqAQ==
254, 140, RelayData, Bank Set the Status of Relays in Bank
This command writes a byte of data directly to a relay bank. This allows
you to easily set the status of 8 relays at one time. RelayData is a
parameter value from 0-255. A value of 0 turns off all the relays. A
value of 255 turns on all the relays. Other values set the status of the
relays in the equivalent binary pattern of the RelayData parameter
value.
NOTE: A Bank Value of 0 applies this command to all relay banks.
Unchecked
Unchecked
Unchecked
Store Power Up Default Status in Bank 1
Dec
/o6qAQ==
This command stores the current status of the relays in a given bank
into memory. The next time power is applied to the controller, relays
will return to the stored on/off state. A bank value of 0 stores the pattern
of all relays in all 26 banks.
Unchecked
Unchecked
Unchecked
Read Power Up Default Status in Bank
Dec
/o8B
254, 143, Bank Read Power Up Default Status in Bank
This command reads the stored power-up default status of the relays in
a given bank. A bank value of 0 reports back 26 bytes of data, indicating
the stored pattern of all 26 relay banks.
Unchecked
Unchecked
Unchecked
Direct Commands to Bank 1
Dec
/jEB
254, 49, Bank Direct Commands to Selected Relay Bank
This command is used to direct commands to a selected relay bank.
Unchecked
Unchecked
Unchecked
Link1
ComPort
COM1
115200
8
None
One
None
1024
1024