LineMode
3000
HH:mm:ss
true
false
false
true
Send:
Rec:
Status:
Red
Black
Blue
0D
HH:mm:ss
false
false
1
1
false
false
false
10
10
CS_FF_A_B
Standard
false
1
true
true
Dec
false
Maximized
1032
776
1676
276
220
false
100
Dec
Unchecked
Unchecked
Unchecked
122
120
297
337
Duration Timer 0
Dec
/jIyAAAFAA==
Setup a duration timer on relay 0 for 5 seconds
Unchecked
Unchecked
Unchecked
Duration Timer 1
Dec
/jIzAAAPAQ==
Setup a duration timer on relay 1 for 15 seconds
Unchecked
Unchecked
Unchecked
Pulse Timer 2
Dec
/jJIAAAFAg==
setup a pulse timer on relay 2 for 5 seconds using timer 2
Unchecked
Unchecked
Unchecked
Duration Timer 0(*)
Dec
/jJaAAAFAA==
Setup a duration timer on relay 0 for 5 seconds
The timer need active using a seprate command
Unchecked
Unchecked
Unchecked
Pulse Timer 2
Dec
/jJwAAAFAg==
setup a pulse timer on relay 2 for 5 seconds using timer 2
Unchecked
Unchecked
Unchecked
Active Timer 0
Dec
/jKDAQA=
active timer 0
Unchecked
Unchecked
Unchecked
Active Timer 2
Dec
/jKDBAA=
active timer 2
Unchecked
Unchecked
Unchecked
Query Timer 0
Dec
/jKCAA==
The Timer Query command is used to view the current status of any
timer. All timers are countdown in nature. Timer Query allows you to
see how much time remains before the timer expires.
Unchecked
Unchecked
Unchecked
Reading the Timer Calibration Value
Dec
/jKF
You may also read the calibration value stored in the controller by issuing
the Calibrator Read command.
This command returns two bytes of
data to the user.
Unchecked
Unchecked
Unchecked
Activating Calibrator Markers
Dec
/jKG
Time calibrator markers are used to help calibrate the timer. When the
calibrator markers have been activated, the controller will send our
ASCII character code 90 at the beginning of any timing event. ASCII
character code 91 will be sent at the end of any timing event. The time
measured between the receiving 90 and 91 is used to help the user set
the calibration value. These markers may prove useful if you need your
PC to know when a timing even has occurred.
Unchecked
Unchecked
Unchecked
Deactivating Calibrator Markers
Dec
/jKH
This command turns off the calibration markers described above.
Unchecked
Unchecked
Unchecked
Setting the Timer Calibration Value
Dec
/jKEAQE=
you can calibrate the timer at any
time. If the controller is in Configuration mode (all dip switches off),
calibration data will be stored when this command is issued. Otherwise,
the calibration value will be changed, but settings will be lost
when power is cycled.
Unchecked
Unchecked
Unchecked
Link1
ComPort
COM1
115200
8
None
One
None
1024
1024